5 Year Extended Warranty
Step 1) Purchase an ION Science Tiger VOC Gas Detector
Step 2) Register your instrument here within one month of purchase
Step 3) Receive a 5 year extended warranty certificate!
Upgradeable Features
The Tiger XT is fully upgradeable, allowing you to add further functionality if required. Upgradable features include Health and Safety mode, PPB Sensitivity, Data Logging, Single Log Only (Push to Log) and Multi Log Only. Tiger XT is fully upgradable without having to return the instrument to the factory.
What’s in the case?
Our standard kits contains the following:-
- Tiger XT Instrument
- Tiger XT Accessory Kit
- USB Cable
- Mains Adaptor with Multiple Plug Adaptors
- Quick Start Guide
- Warranty Registration Card
- Calibration Certificate
- Safety Notice
Technical Specification
Specification | Value |
Minimum Resolution | 10.6 eV: 1 ppb or 0.001 mg/m3*** 11.7 eV: 0.6 ppm (600 ppb)*** |
Detectable Range** |
10.6 eV: 1 ppb up to 20,000 ppm*** 11.7eV: 9,000 ppm***# |
Response Time |
10.6 eV: T90 < 2 seconds 11.7eV: <6 seconds |
Accuracy*** |
10.6 eV: ± 5 % display reading or ± 1 digit*** 11.7 eV: ± 12 % display reading*** |
Approvals |
II 1G Ex ia IIC T4 Ga Tamb = -25 °C ≤Ta ≤ +45 °C (with lithium ion battery pack) Tamb = -25 °C ≤Ta ≤ +40 °C (with alkaline battery pack) IECEx ITS 22.0025X ITS-I22ATEX35111X ITS22UKEX0635X 3193491 conforms to UL Std. 913, 61010-1 & Certified to CAN/CSA Std. C22.2 No. 61010-1 Class 1 Division 1. Approval for Groups A, B, C & D, T4 |
Battery Life | Li-ion: life up to 24 hours, charge time 8 hours Alkaline: 3 x AA, typically 8.5 hours life |
Lamps | 10.6 eV Krypton PID lamp (standard) 10.0 eV and 11.7 eV available |
Data Logging* | 120,000 points including date and stamp |
Communication | Direct USB 1.1 communication |
Calibration | 2 point and 3 point calibration (via calibration kit accessory) |
Alarm | Flashing LEDs Amber (low alarm) Red (high alarm) Sounder 95 dBA at 300 mm (12″) Vibration on alarm programmed TWA and STEL* |
Flow Rate | ≥ 220 ml/min (with blocked flow alarm) |
Humidity | 0-99% RH (non condensing) |
Protection | Designed to IP65 EMC tested to EN61326-1:2013, EN50270:2015 & CFR 47:2008 Class A |
Weight & Dimensions | 370 mm (H) x 91 mm (W) x 60 mm (D) 870g |
* Depends on model and gas.
** Maximum reading is obtained with some analytes such as ethanol.
*** Specifications are based on calibration of isobutylene at 20 ° C and 1000 mBar. All specifications shown are at the calibration point and under the same environmental conditions.
**** Based on continuous operation.
# For indicative measurements only. Quoted accuracy achievable up to 2,000 ppm. For more accurate detection, calibration around the concentration of interest is recommended.