Product Description
Pentane Equivalent Calibration Gas – CO 60 PPM / CH₄ 1.45% (58% LEL) / O₂ 16.0% – 116L Cylinder
This multi-gas calibration mixture is designed for pentane-equivalent LEL calibration, enabling accurate and repeatable validation of gas detectors in hydrocarbon-sensitive and confined space environments.
The blend includes Carbon Monoxide (CO) 60 PPM for precision toxic gas calibration and Methane (CH₄) 1.45% (58% LEL Pentane Equivalent) to simulate detector response aligned with pentane-equivalent combustible gas scaling. Oxygen at 16.0% represents severely reduced atmospheric conditions, ensuring calibration reflects real-world oxygen-deficient environments.
Supplied in a 116L aluminum cylinder at 1000 PSI with a C-10 valve, this configuration is tailored for spec-controlled calibration programs, where exact cylinder size and pressure must be matched for compliance, validation consistency, or contract requirements.
Gas Composition
| Gas | Concentration |
|---|---|
| Carbon Monoxide (CO) | 60 PPM |
| Methane (CH₄) | 1.45% (58% LEL – Pentane Equivalent) |
| Oxygen (O₂) | 16.0% |
| Balance | Nitrogen (N₂) |
Cylinder Specifications
| Specification | Value |
|---|---|
| Cylinder Size | 116 Liters |
| Pressure | 1000 PSI |
| Volume | 4.0 Cubic Feet |
| Material | Aluminum |
| Valve Type | C-10 |
| Gas Reactivity | Non-Reactive |
Applications
- Pentane-equivalent LEL calibration programs
- Spec-matched calibration gas replacement
- Cross-sensitivity detector validation
- Confined space atmospheric simulation
- Industrial hygiene monitoring
Why This Gas Mixture
- Pentane-equivalent scaling → matches real hydrocarbon detector response
- 58% LEL simulation → validates higher-range combustible detection
- CO 60 PPM → precision toxic calibration
- 16.0% O₂ → simulates severe oxygen-deficient environments
- Ensures consistency with validated calibration standards