Product Description
120L 4 Gas Calibration Gas – 40% LEL Methane, CO, O₂ (Primary Field Cylinder)
This 120L 4 gas calibration gas is designed for multi-gas detector calibration under standard atmospheric conditions, featuring 50 PPM Carbon Monoxide (CO), 2.0% Methane (40% LEL), and 20.9% Oxygen (O₂) balanced in nitrogen.
As a 40% LEL methane calibration gas, this mixture allows technicians to perform controlled, lower-range LEL validation, making it ideal for calibration programs requiring graduated sensor response testing.
Gas Composition
- Carbon Monoxide (CO): 50 PPM (Standard Level)
- Methane (CH₄): 2.0% (40% LEL)
- Oxygen (O₂): 20.9% (Atmospheric Baseline)
- Balance Gas: Nitrogen (N₂)
Cylinder Specifications
- Cylinder Size: 120L
- Pressure: 1050 PSI
- Valve: C-10
- Material: Aluminum
- Reactivity: Non-Reactive
Applications
- LEL sensor calibration (partial-range testing)
- Multi-gas detector validation
- Graduated methane calibration programs
- Industrial hygiene monitoring
- Field calibration operations
Why This 120L 40% LEL Cylinder is the Key SKU
- Provides lower-range LEL calibration capability
- Ideal for multi-point calibration strategies
- Balanced for field deployment and runtime
- Covers CO, LEL, and O₂ sensors in one cylinder
- Compatible with C-10 regulated systems
40% vs 50% LEL Calibration
- 50% LEL (2.5% CH₄) → standard calibration
- 40% LEL (this SKU) → controlled, lower-range validation
This SKU is used when precision and range testing matter, not just standard calibration.
Oxygen Context
- 20.9% (this SKU) → baseline atmosphere
- 19.0% → early deficiency
- 18.0% → critical
- 17.0% → severe
120L Field Advantage
- Most practical size for daily calibration work
- Reduces cylinder replacement frequency
- More efficient than smaller cylinders
- More portable than bulk systems