Product Description
CH₄ 1.0% (20% LEL) / Nitrogen (N₂) Balance Calibration Gas
Maintain reliable gas detector performance with CH₄ 1.0% (20% LEL) / Nitrogen (N₂) balance calibration gas, engineered for calibration, bump testing, detector verification, and preventative maintenance of compatible portable and fixed gas detection systems. Packaged in a 17-liter disposable steel cylinder with a 240 PSI fill pressure and CGA-600 valve connection, this non-reactive calibration gas mixture provides a consistent methane concentration for verifying sensor response and maintaining detector accuracy.
Containing 1.0% methane (20% of the Lower Explosive Limit) with nitrogen as the balance gas, this calibration mixture is designed for compatible combustible gas detectors that monitor methane concentrations. Routine calibration using the correct gas standard helps verify sensor response, identify potential instrument drift, and support reliable methane detection in industrial and occupational safety applications.
Calibration Gas Composition
| Gas | Concentration |
|---|---|
| Methane (CH₄) | 1.0% (20% LEL) |
| Balance Gas | Nitrogen (N₂) |
This methane calibration gas is used by industrial hygienists, EHS professionals, maintenance technicians, safety managers, and environmental specialists to calibrate compatible combustible gas detectors. Common applications include oil & gas, petrochemical processing, manufacturing, mining, wastewater treatment, utilities, chemical processing, confined space entry, and other industrial environments where dependable methane monitoring is critical.
Cylinder Specifications
| Specification | Value |
|---|---|
| Cylinder Size | 17 Liters |
| Pressure | 240 PSI |
| Gas Capacity | 0.6 Cubic Feet |
| Valve Connection | CGA-600 |
| Cylinder Material | Steel |
| Cylinder Type | Disposable |
| Reactivity | Non-Reactive |
The 17-liter disposable steel cylinder provides a compact and portable calibration gas solution for field technicians, industrial hygiene programs, confined space teams, and routine detector maintenance. Its 240 PSI fill pressure and CGA-600 connection make it well suited for compatible calibration equipment used for bump testing, detector verification, sensor response checks, and preventative maintenance.
Always confirm the required calibration concentration, regulator, flow rate, and valve compatibility specified by the gas detector manufacturer before use.
If your application requires a different methane concentration, LEL percentage, cylinder size, valve configuration, or specialty gas blend, we manufacture custom calibration gas mixtures for virtually every gas detection application. Contact our team for a quick custom quote if your required mixture is not available in our e-commerce store.