Product Description
Portable Docking Station for Single Gas Clip Gas Detectors
The Single Gas Clip Dock – Portable from Gas Clip Technologies is a high-throughput fleet-management system designed to bump test, calibrate, configure, and log up to four detectors simultaneously, processing as many as 12 instruments per minute.
Housed in a rugged Pelican® transport case, this portable dock is built for contractors, utilities, and safety teams who need full compliance testing capabilities at remote job sites or across multiple facilities—without requiring permanent installation.
With onboard power, internal gas regulation, and USB memory storage, the station operates without a computer while still offering advanced configuration and firmware updates when paired with compatible communication tools.
High-Speed Fleet Testing & Compliance Control
This dock enables safety teams to:
-
Perform simultaneous bump tests on four detectors
-
Group-program alarm setpoints and test intervals
-
Upload firmware updates during testing
-
Maintain audit-ready compliance records
-
Track detector inventories and usage
-
Centralize fleet data management across locations
Key Features
-
Tests 4 detectors at once — up to 12 per minute
-
One-button operation
-
Internal rechargeable battery for hundreds of tests
-
Built-in regulator and pressure gauge
-
2GB USB memory for test & event logs
-
Rugged Pelican® portable case
-
No computer required for daily use
-
Detector configuration & firmware updates supported
-
Designed for mobile safety programs
Programmable Detector Settings
During bump testing or calibration, detectors can be group-programmed for:
-
User ID
-
Calibration interval
-
Bump-test interval
-
Self-test interval
-
Low & high alarm levels
-
Display settings
-
Indicator visibility
-
Clock functions
Event Data & Record Storage
The dock automatically records:
-
All bump tests & calibrations by date, time, and serial number
-
Dock station test history
-
Individual detector event logs
-
Inventory reports
By default, the system stores the previous 10 event logs per detector, exportable via USB memory or supported software platforms.
Communication & Programming Options
Users can communicate with the dock using:
-
USB memory sticks
-
Infrared communication accessories
-
Fleet-management software tools
Infrared interface hardware required for IR-based programming.
System Requirements
-
Windows-based PCs
-
Microsoft .NET Framework 4.0 required